Chapter 4 - Release candidates and beta releases
76 Version 1.6.2a.0 May 17, 2011
Bug Fixes
NWare
Fixed a bug where compile would fail with an unwired cycle breaker device.
Python
Fixed a bug that caused the input.value_set to not take floating point values.
NION
Fixed bug which caused frontpanel to report "IDE OK" when IDE boot actually failed.
Release Beta 10
Features
New Installer.
KLS file (Kiosk Configuration File) is now properly registered. Right-clicking on KLS
files will allow editing in Windows Notepad or opening with NWare:Kiosk.
Right-clicking in Windows Explorer or the Desktop, going to "New" -> "NWare Kiosk
Configuration File" will produce a sample KLS file for you to edit, complete with
comments on how to configure the file.
When muting output cards relays are used in conjunction with the DAC mutes to remove
possible audio pops during deployment.
Deploy, log, and status window now have moveable splitters
When displayed in the GUI, NIONs include their IP address.
Added a pop-up menu with zoom items to NWare Kiosk
The front panel serial port can now be used.
Enabled per channel mutes on CAB 16o by setting channel gain to -95.5 (16o does not
have per channel mute capability built in)
Add event object to threaded python scripts with the following methods (the sleep object
has been removed)
wait( timeout_ms ) - waits timeout_ms
wait_input_change() - waits for input change
wait_input_change( timeout_ms ) - waits for input change. returns true if
an input
changes within timeout_ms, otherwise returns false.
Bug Fixes
Fixed a bug that caused the NION to stop functioning when shutting down with RATC
client(s) connected.
Fixed bug which caused limiters to go into full limit mode and never return.
Fixed flaw that prevented output boards from muting if piond was restarted without a
reboot.
Fixed bug where CAB 4n phantom buttons were not operational.
Fixed bug where room combiners with odd number of rooms would cause the role to not
start ( due to the fact the composite was placing an odd input mixer, which isn't supported
)